CCOHS: Electrical Safety - Basic Information

09 Sep.,2024

 

CCOHS: Electrical Safety - Basic Information

Why is it so important to work safely with or near electricity?

Back to top

The voltage of the electricity and the available electrical current in regular businesses and homes has enough power to cause death by electrocution. Even changing a light bulb without unplugging the lamp can be hazardous because coming in contact with the "hot", "energized" or "live" part of the socket could kill a person.

You can find more information on our web, so please take a look.

What do I need to know about electricity?

Back to top

All electrical systems have the potential to cause harm. Electricity can be either "static" or "dynamic." Dynamic electricity is the uniform motion of electrons through a conductor (this is known as electric current). Conductors are materials that allow the movement of electricity through it. Most metals are conductors. The human body is also a conductor. This document is about dynamic electricity.

Note: Static electricity is accumulation of charge on surfaces as a result of contact and friction with another surface. This contact/friction causes an accumulation of electrons on one surface, and a deficiency of electrons on the other surface. The OSH Answers document on How Do I Work Safely - Static Electricity has more information.

Electric current cannot exist without an unbroken path to and from the conductor. Electricity will form a "path" or "loop". When you plug in a device (e.g., a power tool), the electricity takes the easiest path from the plug-in, to the tool, and back to the power source. This is action is also known as creating or completing an electrical circuit.

What kinds of injuries result from electrical currents?

Back to top

People are injured when they become part of the electrical circuit. Humans are more conductive than the earth (the ground we stand on) which means if there is no other easy path, electricity will try to flow through our bodies.

There are four main types of injuries: electrocution (fatal), electric shock, burns, and falls. These injuries can happen in various ways:

  • Direct contact with exposed energized conductors or circuit parts. When electrical current travels through our bodies, it can interfere with the normal electrical signals between the brain and our muscles (e.g., heart may stop beating properly, breathing may stop, or muscles may spasm).
  • When the electricity arcs (jumps, or "arcs") from an exposed energized conductor or circuit part (e.g., overhead power lines) through a gas (such as air) to a person who is grounded (that would provide an alternative route to the ground for the electrical current).
  • Thermal burns including burns from heat generated by an electric arc, and flame burns from materials that catch on fire from heating or ignition by electrical currents or an electric arc flash. Contact burns from being shocked can burn internal tissues while leaving only very small injuries on the outside of the skin.
  • Thermal burns from the heat radiated from an electric arc flash. Ultraviolet (UV) and infrared (IR) light emitted from the arc flash can also cause damage to the eyes.
  • An arc blast can include a potential pressure wave released from an arc flash. This wave can cause physical injuries, collapse your lungs, or create noise that can damage hearing.
  • Muscle contractions, or a startle reaction, can cause a person to fall from a ladder, scaffold or aerial bucket. The fall can cause serious injuries.

What should I do if I think I am too close to overhead power lines?

Back to top

Do not work close to power lines. Recommended distances vary by jurisdiction and/or utility companies. Check with both your jurisdiction and electrical utility company when working, driving, parking, or storing materials closer than 15 m (49 feet) to overhead power lines.

  • If you must be close to power lines, you must first call your electrical utility company and they will assist you.
  • If your vehicle comes into contact with a power line:
    • DO NOT get out of your vehicle.
    • Call 911 and your local utility service for help.
    • Wait for the electrical utility to come and they will tell you when it is safe to get out of your vehicle.
    • Never try to rescue another person if you are not trained to do so.
    • If you must leave the vehicle (e.g., your vehicle catches on fire), exit by jumping as far as possible &#; at least 45 to 60 cm (1.5 to 2 feet). Never touch the vehicle or equipment and the ground at the same time. Keep your feet, legs, and arms close to your body.
    • Keep your feet together (touching), and move away by shuffling your feet. Never let your feet separate or you may be shocked or electrocuted.
    • Shuffle at least 10 metres away from your vehicle before you take a normal step.
  • Do not enter an electrical power substation, or other marked areas.

What are some general safety tips for working with or near electricity?

Back to top
  • Inspect portable cord-and-plug connected equipment, extension cords, power bars, and electrical fittings for damage or wear before each use. Repair or replace damaged equipment immediately.
  • Always tape extension cords to walls or floors when necessary. Do not use nails and staples because they can damage extension cords and cause fire and shocks.
  • Use extension cords or equipment that is rated for the level of amperage or wattage that you are using.
  • Always use the correct size fuse. Replacing a fuse with one of a larger size can cause excessive currents in the wiring and possibly start a fire.
  • Be aware that unusually warm or hot outlets or cords may be a sign that unsafe wiring conditions exists. Unplug any cords or extension cords from these outlets and do not use until a qualified electrician has checked the wiring.
  • Always use ladders made with non-conductive side rails (e.g., fibreglass) when working with or near electricity or power lines.
  • Place halogen lights away from combustible materials such as cloths or curtains. Halogen lamps can become very hot and may be a fire hazard.
  • Risk of electric shock is greater in areas that are wet or damp. Install Ground Fault Circuit Interrupters (GFCIs) as they will interrupt the electrical circuit before a current sufficient to cause death or serious injury occurs.
  • Use a portable in-line Ground Fault Circuit Interrupter (GFCI) if you are not certain that the receptacle you are plugging your extension cord into is GFCI protected.
  • Make sure that exposed receptacle boxes are made of non-conductive materials.
  • Know where the panel and circuit breakers are located in case of an emergency.
  • Label all circuit breakers and fuse boxes clearly. Each switch should be positively identified as to which outlet or appliance it is for.
  • Do not use outlets or cords that have exposed wiring.
  • Do not use portable cord-and-plug connected power tools if the guards are removed.
  • Do not block access to panels and circuit breakers or fuse boxes.
  • Do not touch a person or electrical apparatus in the event of an electrical incident. Always disconnect the power source first.

What are some tips for working with power tools?

Back to top
  • Switch all tools OFF before connecting them to a power supply.
  • Disconnect and lockout the power supply before completing any maintenance work tasks or making adjustments.
  • Ensure tools are properly grounded or double-insulated. The grounded equipment must have an approved 3-wire cord with a 3-prong plug. This plug should be plugged in a properly grounded 3-pole outlet.
  • Test all tools for effective grounding with a continuity tester or a Ground Fault Circuit Interrupter (GFCI) before use.
  • Do not bypass the on/off switch and operate the tools by connecting and disconnecting the power cord.
  • Do not use electrical equipment in wet conditions or damp locations unless the equipment is connected to a GFCI.
  • Do not clean tools with flammable or toxic solvents.
  • Do not operate tools in an area containing explosive vapours or gases, unless they are intrinsically safe and only if you follow the manufacturer's guidelines.

What are some tips for working with power cords?

Back to top
  • Keep power cords clear of tools during use.
  • Suspend extension cords temporarily during use over aisles or work areas to eliminate stumbling or tripping hazards.
  • Replace open front plugs with dead front plugs. Dead front plugs are sealed and present less danger of shock or short circuit.
  • Do not use light duty extension cords in a non-residential situation.
  • Do not carry or lift up electrical equipment by the power cord.
  • Do not tie cords in tight knots. Knots can cause short circuits and shocks. Loop the cords or use a twist lock plug.

What is a Ground Fault Circuit Interrupter (GFCI)?

Back to top

A Class A Ground Fault Circuit Interrupter (GFCI) works by detecting any loss of electrical current in a circuit (e.g., it will trip at a maximum of 6mA). When a loss is detected, the GFCI turns the electricity off before severe injuries or electrocution can occur. A painful non-fatal shock may occur during the time that it takes for the GFCI to cut off the electricity so it is important to use the GFCI as an extra protective measure rather than a replacement for safe work practices.

GFCI wall outlets can be installed in place of standard outlets to protect against electrocution for just that outlet, or a series of outlets in the same branch circuit. A GFCI Circuit Breaker can be installed on some circuit breaker electrical panels to protect an entire branch circuit. Portable in-line plug-in GFCIs can be plugged into wall outlets where appliances will be used.

When and how do I test the Ground Fault Circuit Interrupter (GFCI)?

Back to top

It is important that you follow the manufacturer's instructions with respect to the use of a GFCI.  Test permanently wired GFCIs monthly, and portable devices before each use. Use a GFCI tester. You may also test by pressing the "test" and "reset" buttons. Plug a "night light" or lamp into the GFCI-protected wall outlet (the light should turn on), then press the "TEST" button on the GFCI. If the GFCI is working properly, the light should go out. If not, have the GFCI repaired or replaced. Press the "RESET" button on the GFCI to restore power.

Contact a qualified electrician if you are unsure or to correct any wiring errors.

What is a sample checklist for basic electrical safety?

Back to top

Inspect Cords and Plugs

  • Check extension cords and plugs daily. Do not use, and discard cords and plugs if they are worn or damaged.
  • Have any extension cord that feels more than comfortably warm checked by an electrician.

Eliminate Octopus Connections

  • Do not plug several items into one outlet.
  • Pull the plug, not the cord.
  • Do not disconnect power supply by pulling or jerking the cord from the outlet. Pulling the cord causes wear and may cause a shock.

Never Break OFF the Third Prong on a Plug

  • Replace broken 3-prong plugs and make sure the third prong is properly grounded.

Never Use Extension Cords as Permanent Wiring

  • Use extension cords only to temporarily supply power to an area that does not have a power outlet.
  • Keep extension cords away from heat, water and oil. They can damage the insulation and cause a shock.
  • Do not allow vehicles to pass over unprotected extension cords. Extension cords should be put in protective wireway, conduit, pipe or protected by placing planks alongside them.
  • Fact sheet last revised: -09-20

A Free Guide to Data Center Power

The term &#;data center power&#; refers to the infrastructure, systems, and processes used to provide and manage power in a data center. This includes power supply distribution, backup systems, and management tools to ensure that the data center can operate continuously and effectively without any interruptions. 

It&#;s pretty obvious that an adequate supply of high-quality power is critical to ensuring the availability and reliability of the data center&#;s IT equipment and services. Data center power depends equally on two fundamental pillars: power infrastructure and power management. Each discipline has its own setup planning considerations, procedures, configurations, and best practices.

In this article, we take a detailed look at various aspects of power in data centers. This includes a look at power usage, power efficiency metrics, power infrastructure, management, cost considerations, standards, and much more.

Key data center power metrics concepts

Power density

The amount of power that can be supplied to a specific area or rack within the data center.

Power capacity

The maximum amount of power that a data center can supply to all its equipment without causing an overload or failure.

Redundancy

The duplication of critical power infrastructure components and systems to ensure the uninterrupted supply of power in the event of a failure or outage.

Power efficiency

A measure of how efficiently power is utilized within the data center infrastructure. Improving efficiency involves minimizing power waste and maximizing the utilization of electrical energy for productive purposes.

Power distribution

The process of distributing power to the IT equipment within the data center.

Power monitoring

The tools and systems used to monitor power usage, temperature, and humidity levels within the data center to prevent power failures or outages.

Power management

The process of managing power usage, load balancing, and other aspects of power distribution to optimize efficiency.

Key performance indicators (KPIs) used to measure power efficiency

Power usage effectiveness (PUE)

A metric that measures the total power usage of the data center and compares it to the power used by IT equipment.

Energy efficiency ratio (EER)

The ratio of cooling output to power input; a higher EER indicates better cooling efficiency.

Reliability

A general measure of the probability of a component or system operating according to specifications during a particular time interval.

Availability

The percentage of time that a component or system operates within designated parameters.

Mean time between failures (MTBF)

The average time between two or more failures of a system or component.

Mean time to repair (MTTR)

This is the average time it takes to repair a component or system failure. A lower MTTR means the system can be restored to service more quickly.

Carbon usage effectiveness (CUE)

Measures the amount of carbon dioxide emitted per kilowatt-hour of energy used by the data center.

Overview of power usage in data centers

Understanding power usage and the importance of its monitoring

Power is used in a data center to run IT equipment (e.g., servers, storage devices, and networking equipment); cooling systems such as air conditioners, computer room air handler (CRAH) units, and chillers; and supporting infrastructure such as power distribution systems, backup power systems, lighting, and other equipment. Of these various components, cooling actually uses the most power, about 50% of the total.

Typical breakdown of power usage in a data center. (Source)

Since the level of power consumption in a data center is substantial, it represents a significant operating expense. It is essential to monitor and optimize power usage for several reasons:

  • Cost management:

    Monitoring and optimizing power usage in data centers can help reduce operating costs associated with electricity consumption, resulting in significant savings for the organization.

  • Capacity planning:

    Power usage monitoring can help in capacity planning and identifying potential bottlenecks or areas for improvement.

  • Environmental sustainability:

    By managing power consumption, data centers can have their carbon footprints reduced, contributing to the sustainability efforts of the organization.

  • Performance optimization:

    Proper power management can improve the performance of the data center by reducing the risk of power-related downtime.

Determining power requirements

Determining the requirements for data center power includes calculating the IT equipment&#;s power consumption, the needs of the cooling system, and how much power is being used by the supporting infrastructure. Here are some steps to determine power requirements for a data center:

  • Estimate the IT load:

    Determine the amount of power required to run the IT equipment, including servers, storage, and networking gear.

  • Determine cooling system power requirements:

    The cooling system&#;s power requirements depend on the amount of heat generated by the IT equipment and the desired temperature range within the data center. Typically, cooling systems require as much as 50% of the data center&#;s total power usage.

  • Calculate supporting infrastructure power usage:

    Compute the total power needed for supporting infrastructure components such as lighting, security systems, backup power systems, etc.

  • Employ redundancy:

    Redundancy is essential to ensure continuous uptime; it involves duplicating some components of the power system to ensure that there is always a backup in case of failure.

When determining power requirements, it is also important to consider the future in order to ensure both that the data center&#;s power supply can meet current power needs and that there is enough capacity to handle future growth.

Single-phase vs. three-phase power

The choice between single-phase and three-phase power in a data center depends on factors such as the size of the facility, power requirements, equipment types, and future scalability needs. Data centers with high-density computing and heavy power loads often opt for three-phase power to accommodate their energy demands effectively. This is due to the power balance achieved in three-phase systems.

Power balance refers to the equal distribution of power among the different phases or circuits. Power imbalance in a system can lead to issues such as uneven heating of equipment, increased losses, and reduced system efficiency. It&#;s important to note that power balance considerations become more critical in three-phase systems due to the higher power capacity and the need for equal distribution of loads among the phases, which is what makes them better suited to larger installations.

Some key differences between single-phase and three-phase power in the context of data center power are shown in the table below.

 

Single-phase power

Three-phase power

Voltage

Typically 120V or 240V in data center applications

Typically 208V or 415V in data center applications

Power capacity

Lower power capacity

Higher power capacity

Power distribution

Generally used for smaller equipment

Suitable for larger equipment and servers

Efficiency

Lower efficiency due to imbalanced power flow

Higher efficiency due to balanced power flow

Complexity and cost

Simpler and less expensive to install and maintain

More complex and potentially costlier to implement

Scalability

Limited scalability for higher power demands

Scalable for larger data center facilities and future growth

Industry applicability

Commonly used in smaller data centers or office environments

Commonly used in larger data centers and enterprise settings

Download the Next Generation CMDB with Integrated Service Dependency Mapping

FREE DOWNLOAD

Power infrastructure

Let&#;s begin our discussion of power infrastructure with a look at some of the most common types of power equipment in data centers:

  • Transformers:

    Transformers are used to step up or step down voltage levels between the utility power feed and the data center electrical distribution system. They ensure that the power received from the utility is compatible with the data center&#;s requirements.

  • Power distribution units (PDUs):

    An essential component of data center power infrastructure used to distribute electrical power to multiple devices or equipment. A PDU serves as a central point for power distribution, receiving electricity from a primary power source and delivering it to IT load and other critical equipment.

  • Power cables and connectors:

    These simple devices connect the power equipment to the IT equipment.

  • Power breakers:

    Also known as circuit breakers, they are designed to protect electrical equipment from overcurrent or short-circuit conditions.

  • Uninterruptible power supplies (UPSes):

    A UPS provides power backup to IT equipment during power interruptions such as outages, overvoltage or undervoltage conditions, sags, and swells. It consists of a battery backup system and an automatic transfer switch that switches the load to the battery when there is a power failure.

  • Backup generators:

    Generators provide backup power in the event of prolonged power outages that exceed the capabilities of UPS systems.

    If you are looking for more details, kindly visit Sager.

  • Automatic transfer switches (ATSes):

    An ATS is a device that automatically switches the load between primary utility power and an alternate power source such as a generator (in the event of a power disruption).

Data center tiers and the importance of redundancy and backup systems

Redundancy and backup systems minimize downtime, maintain business continuity, mitigate risk, and ensure compliance with regulatory requirements. Data centers are classified into a four-tier system, which provides a standard way to measure redundancy and backup capabilities and, thus, compare the redundancy, fault tolerance, and availability of different data center types. Higher tiers indicate more capability and less potential business disruption, but they also require more investment in infrastructure and maintenance. 

The Uptime Institute designed these tiers and certifies data centers as official tier facilities. Not all data centers are certified by the Uptime Institute (which created the &#;tier&#; terminology) and hence use the term &#;level&#; instead, which is equivalent. The tiers are shown in the table below.

Tier Description Expected uptime percentage Expected annual downtime (hours) 1

A Tier 1 data center uses basic infrastructure and offers minimal redundancy. It is typically a single path for power and cooling and does not have redundant components. 

99.671%

28.8

2

A Tier 2 data center offers some redundancy and provides some level of fault tolerance. It has redundant components, such as backup power and cooling systems, but may not have redundant paths for power and cooling. 

99.741%

22

3

A Tier 3 data center provides a high level of redundancy and is designed to be concurrently maintainable. It has multiple paths for power and cooling and redundant components that can be taken offline without affecting loads. 

99.982%

1.6

4

A Tier 4 data center provides the highest level of redundancy and fault tolerance. It has multiple paths for power and cooling and fully redundant components that are designed to be fault tolerant.

99.995%

0.4

Scalability

Power scalability is a critical consideration for data center operators as they plan for growth and expansion. By considering power density, modular design, power distribution, energy efficiency, and power monitoring, data center operators can ensure that the power infrastructure is designed to accommodate increasing power demands in a cost-effective and efficient manner.

Let&#;s take a simple scenario to understand this. Suppose a data center is currently running at 50% of its power capacity, with 1 MW of power being used to support the IT infrastructure. However, the organization is planning to increase its IT workload, which will require an additional 500 kW of power. To accommodate this additional power requirement, the data center operator has the following options:

  • Upgrade the power infrastructure.

  • Use a modular data center design to add more power capacity.

  • Improve energy efficiency by upgrading to more energy-efficient systems.

  • Monitor power usage in the data center to identify areas of inefficiency and adjust accordingly.

Ultimately, the decision on what option to choose would be based on a comprehensive analysis of a variety of different factors. It will involve assessing future power capacity needs, budget, flexibility requirements, energy efficiency and sustainability goals, and overall business continuity requirements and timelines. A scaling project will also involve consulting with experts such as electrical engineers, data center consultants, and equipment vendors, to gather more insights and recommendations to support the expansion.

Power distribution

A data center typically receives power from the utility grid at high voltage and then distributes it to the IT equipment at a lower voltage. Power is distributed through a series of equipment connected to the data center&#;s servers and other gear.

Data center power distribution system and components

Here&#;s a breakdown of how power is distributed in a data center:

Free white paper: IT Asset discovery best practices

Download Free

  • Utility power:

    The data center

    receives power from utility grid through a main electrical service entrance. The incoming power is typically high voltage (e.g., 13.8 kV or 33 kV) and is stepped down by transformers to a lower voltage.

  • Electrical switchgear:

    The power is then delivered to the electrical switchgear, such as an automatic transfer switch, which distributes power to the UPS system.

  • Generator:

    A generator acts as a backup source of power, with the ATS transferring load between backup and utility power as needed.

  • UPS:

    The UPS system provides backup power in the event of a power outage or interruption. The UPS system also conditions the power to ensure that it is stable and free from surges, spikes, and other electrical disturbances.

There is usually a delay of 10 to 15 seconds in getting generators up and running in the event of utility power outage. UPS systems provide a cushion during this delay and then linearly transfer the load to generators as they come up.

  • Power distribution units (PDUs):

    The power is then distributed to the IT equipment through power distribution units (PDUs).

  • Remote Power Panel (RPP):

    An RPP distributes electrical power from PDUs to individual rack-mounted power distribution units (rPDUs) or directly to the equipment. It serves as an intermediate point between the main power source and the equipment, providing a convenient and localized power distribution solution. 

Cost considerations and management

Power and cooling costs are a significant percentage of overall data center expenses. To help monitor and manage costs, most providers rely on data center infrastructure management (DCIM) software that lets them monitor and manage power consumption and other resources in real time. Using these tools in conjunction with effective monitoring strategies allows data centers to reduce energy costs and improve their power usage effectiveness (PUE) scores, which measure the efficiency of a data center&#;s power usage. The closer the PUE is to 1, the more efficient the data center is in its use of power.

The following are some ways that DCIM and other power monitoring strategies can help manage costs in a data center:

  • Real-time monitoring

  • Power usage tracking

  • Temperature and humidity monitoring

  • Predictive analytics to forecast future power usage

  • Power load balancing

Power management best practices and tools

Effective power management requires a combination of best practices and tools, such as the following.

  •  

    Implement a power management plan:

    Create a comprehensive strategy that outlines procedures for managing power consumption, optimizing efficiency, and ensuring uptime.

  • Conduct regular audits:

    Energy audits can provide a detailed analysis of the data center&#;s energy usage, including recommendations for improving efficiency and reducing costs.

  • Use virtualization technologies:

    Technologies such as server virtualization can help reduce power consumption by consolidating workloads onto fewer physical servers. This not only reduces energy usage but also saves space and reduces the need for additional hardware.

  • Implement power capping:

    Implement power capping to limit the maximum amount of power that a server or system can consume, which can prevent power spikes and improve efficiency.

  • Invest in renewable energy integration systems:

    To reduce power expenditures and promote sustainability, many data centers are investing in renewable energy sources such as solar, wind, or hydro power.

  • Use energy-efficient hardware:

    Using energy-efficient hardware lets data centers reduce energy consumption and save on costs in the long run.

  • Implement intelligent power management:

    Intelligent power management tools can automatically monitor power usage and adjust power settings as needed to optimize efficiency.

  • Employ power management software tools:

    Applications that help manage and monitor power consumption in data centers can provide real-time information on power usage and environmental conditions, allowing administrators to optimize power usage and reduce energy costs.

Here are some specific types of systems that can be valuable in managing data center power: 

  • Data center infrastructure (DCIM) software:

    A comprehensive software suite used to manage and monitor various data center infrastructure components, including power and cooling systems, IT equipment, and environmental sensors. DCIM provides real-time information on the performance of various systems and can thus help optimize energy usage, reduce downtime, and increase efficiency.

  • Server power management software:

    This software is specifically designed for managing the power usage of individual servers within a data center. It can be used to adjust power usage settings based on server usage levels.

  • Energy management systems (EMS):

    EMS is a broader term that refers to a range of software and hardware tools used to manage and optimize energy usage across an organization. In the context of data centers, an EMS would include both DCIM and server power management software as well as tools to manage power usage.

Current and emerging trends

The following are some up-and-coming trends impacting the world of data center power.

Green energy

Many data centers are now turning to renewable energy sources like solar and wind power to reduce their reliance on traditional power sources.

Energy storage systems 

Energy storage systems, such flow batteries, thermal storage, and flywheels, can be used to store excess energy generated by renewable sources like solar and wind. The stored energy can then be used during periods of high demand or when traditional power sources are unavailable.

Artificial intelligence

AI can help identify inefficiencies and patterns in power usage, enabling data center operators to take proactive measures to reduce energy waste and improve efficiency. For example, ML algorithms can analyze data from sensors and other sources to identify opportunities to optimize cooling, lighting, and power-intensive hardware.

Liquid cooling

Liquid cooling technologies are emerging as an alternative to traditional air-cooling methods. They can be more efficient and require less energy to operate.

Direct current (DC) power distribution within the data center

Direct current (DC) power distribution within the data center refers to the use of DC electrical power to supply energy to the IT equipment and components instead of the traditional alternating current (AC) power. In this approach, DC power is distributed directly from the power source to the equipment without the need for AC-DC conversion. The use of DC power distribution within the data center can have several benefits:

  • Energy efficiency

    : DC power distribution eliminates the need for multiple AC-DC conversions, which reduces energy losses associated with conversion processes.

  • Simplified power infrastructure

    : DC power distribution simplifies the power infrastructure by eliminating the need for multiple AC PDUs and transformers. 

  • Increased rack density

    : DC power distribution allows for higher rack densities and increased power delivery to IT equipment.

  • Improved reliability

    : DC power distribution can enhance reliability by eliminating potential points of failure associated with AC-DC conversion components.

Industry energy standards

  • ASHRAE TC 9.9:

    Provides guidelines for data center environmental conditions, including temperature and humidity levels.

  • The Green Grid:

    Provides standards and best practices for energy-efficient data center design and operation.

  • Energy Star:

    Provides guidelines for energy-efficient equipment and practices.

  • ISO :

    Provides a framework for implementing an energy management system to optimize energy usage.

  • IEC and NEMA:

    Provide standards for electrical equipment, including ODUs, UPSes, and other devices used in data centers.

  • Leadership in Energy and Environmental Design (LEED):

    Primarily focuses on overall building sustainability and energy efficiency criteria.

  • EU Code of Conduct:

    Provides guidelines and best practices to optimize energy consumption, reduce greenhouse gas emissions, and improve overall operational efficiency.

Discovery, Asset Management & Dependency Mapping for Data Center and Cloud

Learn More

Fastest time to value with easy implementation and agentless asset discovery

Comprehensive hardware and software inventory management

Broadest discovery from legacy technology to the latest cloud and containers

Recommendations and conclusion

Data center power management is a critical aspect of operating a modern data center. Power consumption represents a significant portion of a data center&#;s operating costs and environmental impact, so it&#;s important to adopt best practices and use the latest tools and technologies to optimize power usage.

Some key recommendations for effective data center power management include the following:

  • Conduct regular energy audits to identify opportunities for improvement.

  • Use DCIM to monitor and optimize power usage.

  • Implement virtualization technology to help reduce power usage and increase energy efficiency.

  • Adopt a power management plan that includes monitoring, measurement, and optimization strategies.

  • Invest in energy-efficient equipment.

  • Implement energy storage and renewable energy solutions to reduce dependence on the grid and increase resilience.

  • Leverage AI and machine learning to optimize power usage and reduce costs.

  • Use DC power distribution within the data center to improve efficiency and reliability.

  • Educate data center operations staff on power management and energy efficiency. This is a crucial best practice that helps eliminate energy waste, optimize power usage, and reduce operating costs and can be implemented through training programs, workshops, and ongoing education initiatives.

As the data center industry continues to grow and evolve, it will be increasingly important to adopt these strategies and use the latest tools and technologies to ensure that data centers are able to operate efficiently, effectively, and sustainably for years to come.

Are you interested in learning more about power socket rail? Contact us today to secure an expert consultation!